M16 Threaded Rod Load Capacity

Gi threaded rod weight chart threaded rod weight chart and metric threaded rod weight chart fully threaded rods weight chart fully threaded unc astm studs weight chart fully threaded rods size in mm weight per metre.
M16 threaded rod load capacity. Note that hangers supporting steam water air or gas piping systems should be able to carry the weight of piping insulation valves and other equipment. 47th street new york new york wt 100 ft. Info muepro de contact form call back service. 49 61 22 47 02 email.
When used for suspension they are threaded into an anchor in the ceiling and. 1 the maximum loads in the table above are based on allowable tensile stress of 12 kpsi reduced by 25 to 9 kpsi allowable stress. Threaded rods can be used in both anchoring and suspension applications. Fasteners bolts nuts and threaded rods torque tension and loads.
Metric bolt grades and strength calculator to show proof strength tensile strength vickers brinell hardness minimum breaking torque and stress area of metric bolts and screws made of carbon steel and alloy steel with designations 4 6 4 8 5 8 8 8 9 8 10 9 and 12 9. Once fastened they resist loosening from counterclockwise motion. These metric threaded rods tighten when turned to the left. The shear capacity of the bolt is given by.
P nom 0 8p t a t nominal. Hanger support spacing rod sizes horizontal pipes. In the table as has been taken as equal to at. Müpro services gmbh hessenstrasse 11 65719 hofheim wallau germany telephone.
Dimensions sizes and dimensions of pipes and tubes and their fittings inside and outside diameter weight and more. Max rec load lbs 600 f 750 f 1 4 20 0 12 240 210 3 8 16 0 29 610 540 1 2 13 0 54 1130 1010 5 8 11 0 83 1810 1610 3 4 10 1 25 2710 2420. P t is the tension strength of the bolt. P s is the shear strength of the bolt a s is the shear area of the bolt.
P s p s a s. Hilti anchor rod specifications hit v has and hit z anchor rods 2 hilti inc. Force newton s third law mass and acceleration. Threaded rods proof load capacities in metric units.
1 800 363 4458 i www hilti ca i hilti anchor rod technical data 03 14 specifications and physical properties of hilti hit v has and hit z threaded rods. 1 kg 9 81 n. 49 61 22 80 80 fax. Mass and weight the difference.
Steel threaded rod load carrying capacity of threaded hot rolled steel conforming to astm a575 and a576 extracted from american standard code for pressure piping asa b31 1 1973 with permission of the publisher the american society of mechanical engineers united engineering center 345 e. Bolt torque calculator calculate required bolt torque.